Area of Application
The thermo switch O is used whenever switch-on function is needed, caused by overheating or increasing temperature. Specific applications include: cooling fan, alarm signal, controller, timer.
Mounting brackets or clips available.
Function
The thermo switch O operates not current sensitive. Temperature detection is realized by a bimetal snapdisc. When the switch-on temperature TE is reached, the bimetal disk will snap over to close a contact system. After cooling down and reaching the cut-off temperature TA, the bimetal disk will automatically return to its initial position and open the contacts again.
Breaking capacity: | 250 V; 1,0 A / 50 Hz |
Min. current: | 20 mA |
Switching temperature: | 50°C – 130°C (±10) in 5 Kelvin steps |
Switching differential: | 10 K to 60 K depending from switch on temperature |
max. ambient temperature: | 160°C / 200°C, 1 minute |
Approvals: | VDE (EN 60730), conform to RoHS |