FEATURE | DESCRIPTION |
Tracking Accuracy | Normally more than 10% of receive 3 dB beam width RMS, in Step track mode. |
Position Encoding | Single-speed, brushless resolves and 16-bit track type RDC integrated circuit (IC), Accuracy≤0.05°RMS. |
Display Resolution | 0.01° |
Position Encoding Repeatability | Typically 1 LSB of resolver-to-digital conversion resolution |
Input Power Requirements | Drive Unit: 380V AC, three-phase, 50-60Hz, 5 cores. Power depending on the configuration of the drive motor. ACU: 220V AC, 50-60Hz, 100VA (Normal), Other power supply standard optional, can be declared in the orders. |
Power Range | 1/2~20HP (Depending on the antenna diameter) |
ACU & Tracking Receiver Interface | Analog(standard): Single -5~5 VDC analog input; 0~10VDC analog input optional, to be declared in the orders |
Remote Communication Interface | Remote control RS-232/485 serial port, or Ethernet interface options, to be declared in the orders. |
System Cable | ACU / Drive unit interface; RVVP0.3 mm2×10 Resolver / ACU: RVVP 6×0.3 mm2 Motor: YZ 0.7 mm2×3 (depending on motor power) Limit: RVV0.3 mm2×3 Standard system includes a 30-meter-long cable, up to 100 meters, to be declared in the orders |
Environmental | ACU: Temperature -45°C ~ 65°C; 90% humidity non-condensing ADU: Temperature -55°C ~ 85°C (-45°C to have low-temperature heating equipment, optional); 99% non-condensing humidity. |