The Reformulyzer M4 determines full group type analysis of gasoline and gasoline blend streams using multi-dimensional gas chromatography. It is the fastest and most flexible analyzer on the market to combine analysis for Paraffins, Olefins, Naphthenes, Oxygenates, and Aromatics in one instrument. The M4 is the only solution that truly meets today’s lab challenges, including time-savings, flexibility, and product value optimization. It provides these key benefits through:
High performance
Maximum instrument uptime
Improved ease of use and flexibility
Proven compliancy
The M4’s most significant advancement is its reduced analysis time. Other group type analysis instruments take 75 minutes to run. The M4 reduces this by approximately 50% to 39 minutes. Faster group type analysis allows for refineries to make important decisions quickly to ensure the end product produced is on spec. In addition, independent laboratories are able to almost double their sample capacity and therefore their revenue.
NEW!! The AC Reformulyzer M4 is now available on the new Agilent 8890 GC Platform.Intelligent capabilities built into the Agilent 8890 GC give you the freedom to work with your GC… not on it. These capabilities can also grow over time as your analytical needs change—so you can keep your lab moving toward a successful future.
In addition to increasing revenue, the M4 can reduce analysis costs. Its advanced technology significantly reduces maintenance and system down-time. When combined with the improved sample capacity, the total operational cost per sample is reduced by 50%.
ApplicationsMultidimensional Group Type, Aromatics, Olefin, Oxygenates, Gasoline Characterization, Gasoline
Excellent Performance with High Value of Return
Increases Profits with Fast and Accurate Analysis in 39 minutes for fast decision-making on product specification
Robust design reduces operational cost per sample
Excellent precision and accuracy contribute to higher profitability
Extensive analysis scope from one single instrument
Maximum System Uptime through Robust and Intelligent Design
Excellent olefin trap robustness for superior trap lifetime
Nitrogen carrier saves cost and avoids helium supply chain risks
Diagnostic Tool and certified AC quality control samples for system performance verification
Improved Ease of Use and More Flexibility
Standard olefin method covers entire concentration up to 75%
User-friendly design allows easy preventive maintenance by operator
Intuitive Reformulyzer software includes extensive range of methods and pre-programmed modes
Unique Reformulyzer User Group with interlaboratory comparison contributes to high confidence level and a strong QC program