(LQS)防爆安溫度計(jì)34米 型號(hào): IC01-TP-7C庫(kù)號(hào):M295474 (LQS)防爆安溫度計(jì)34米 型號(hào): IC01-TP-7C庫(kù)號(hào):M295474 (LQS)防爆安溫度計(jì)34米 型號(hào): IC01-TP-7C庫(kù)號(hào):M295474
防爆安溫度計(jì)(Standard Weight Probe)34米 型號(hào): IC01-TP-7C
庫(kù)號(hào):M295474 查看hh
midwest-group
midwest-group
TP7-C
?
大尺寸:34.3 x 18.4 x 11.4 cm??
2節(jié)AA堿性電池,壽命大約200小時(shí)
電池操作溫度范圍4到130°F,20至54°C
注:如果環(huán)境溫度很低或高電池不可能提供充足的電力。
?
表殼材質(zhì):聚丙烯共混材料,不銹鋼和鋁?
?
內(nèi)置鉑電阻的不銹鋼傳感器外有防靜電電纜套管,芳綸纖維加強(qiáng)了抗切割和耐碎性。?
電纜采用碳氟化合物,如FEP、PFA或相似材料作為絕緣材料?
溫度:溫度范圍:-40 to +204°C
分辨率:0.1℃,
誤差:±0.1°C from 0 to 100°C
±0.3°C from 100 to 200°C
長(zhǎng)期精確度漂移不過(guò) 0.05%/年?
符合API要求
安等級(jí):II 2 (1) G Ex ib[ia] IIB T4
The TP7-C employs the proven RTD design that has been used in the TP 7 and TP 8 for many years. A sealed industrial quality overlay provides a user interface that is easy to use with gloves. A polypropylene blend enclosure protects the circuit board and large LCD from penetration by impact, water and reactive liquids.
The new TP 7-C circuit board is an evolutionary step up from our highly accurate, reliable and successful TL1 laboratory thermometer. The Power Button’s primary function powers the instrument for intervals of about 20 minutes since the last button was accessed. The Power Button can also be used to conserve power and clear the memory, or to make adjustment while in calibration mode. A simple menu operation is displayed by holding the Function Button, and alternay functions to allow adjustments in the calibration mode. Arrows on the left side of the display show the direction of the temperature reading and whether stability has been reached. At the user’s discretion stabilized temperatures can be logged at numerous liquid levels for a running average and later displayed for the user’s documenting purposes. But this feature never interferes with simply getting an accurate temperature reading.
To endure the environment and be intrinsically safe, the TP 7-C is manufactured of materials, which are both immune to petrochemicals and are non-sparking. The enclosure is made of a polypropylene blend. The probe assembly is constructed using non-stick cable and stainless steel sensor components.
Operational Attributes:
Easily replaceable AA Batteries, provides an estimated *200 hours operation.
Circuit logic automatically indicates low battery condition, automatically shuts off after twenty minutes, shows temperature trend and stabilization, displays error codes for failure determination.
The low power backlight for night operation is photo sensor controlled for convenience and battery conservation.
In nighttime conditions the backlight illuminates the display.
Celsius or Fahrenheit units with C/F indication can be easily selected from the Function Button.
User Manual explains intuitive calibration procedure that can be done through the external faceplate buttons.
Specifications
Maximum Dimensions:
13.5 x 7.25 x 4.5 in.
34.3 x 18.4 x 11.4 cm
Probe:
304 Stainless Steel, Sealant, Aramid Fiber Reinforced, FEP or PFA
Cable Jacket, Coaxial Construction
Enclosure Material:
Polypropylene Blend, Stainless Steel and Aluminum.
Batteries:
2 AA Alkaline; Battery Life of approximay
200 hours
Battery manufacturer’s battery operating temperatature range -4 to 130°F, -20 to 54°C
Note: Battery may not provide adequate power if ambient temperature is extremely low or high.
Temperature:
Resolution 0.01
Range: -40 to +400°F
-40 to +204°C
Calibrated Accuracy:
±0.2°F from 32 to 200°F
±0.5°F from 200 to 400°F
±0.1°C from 0 to 100°C
±0.3°C from 100 to 200°C
4 Point NIST Traceable Report of Test
Long-term drift not to exceed 0.05%/year
Meets API requirements集團(tuán)
集團(tuán)