A47H帶扳手彈簧微啟式安全閥概述:
A47H型帶扳手彈簧微啟式安全閥適用于工作溫度≤350℃的蒸汽、空氣等介質(zhì)的設(shè)備或管路上。帶扳手彈簧微啟式安全閥作為超壓保護(hù)裝置。連接法蘭標(biāo)準(zhǔn)按JB/T-94的系列1。
A47H帶扳手彈簧微啟式安全閥主要材質(zhì):
零件名稱 | 材料 |
閥體 | WCB |
閥座 | ZG2Cr13 |
調(diào)節(jié)圈 | ZG2Cr13 |
閥瓣 | 2Cr13 |
導(dǎo)向套 | 2Cr13 |
閥蓋 | ZG230-450 |
彈簧 | 50CrVA |
閥桿 | 2Cr13 |
扳手 | ZG200-400 |
調(diào)整螺桿 | 45 |
保護(hù)罩 | ZG200-400 |
密封面材料 | "H"堆焊D507,"Y"堆焊Co基硬質(zhì)合金 |
A47H型帶扳手彈簧微啟式安全閥尺寸:
A47H型帶扳手彈簧微啟式安全閥外形尺寸:
型號(hào) | 公稱通徑 | do | D | K | g1 | b | f | Z-ød | DN' | D1 | K1 | g2 | b1 | f' | Z1-ød1 | L | L1 | ≈H |
A47H-16C | 20 | 15 | 105 | 75 | 55 | 16 | 2 | 4-14 | 20 | 105 | 75 | 55 | 16 | 2 | 4-14 | 100 | 85 | 270 |
25 | 20 | 115 | 85 | 65 | 16 | 2 | 4-14 | 25 | 115 | 85 | 65 | 16 | 2 | 4-14 | 100 | 85 | 270 | |
32 | 25 | 140 | 100 | 78 | 18 | 2 | 4-18 | 32 | 140 | 100 | 78 | 18 | 2 | 4-18 | 115 | 100 | 312 | |
40 | 32 | 150 | 110 | 85 | 18 | 3 | 4-18 | 40 | 150 | 110 | 85 | 18 | 3 | 4-18 | 120 | 110 | 320 | |
50 | 40 | 165 | 125 | 100 | 20 | 3 | 4-18 | 50 | 165 | 125 | 100 | 20 | 3 | 4-18 | 135 | 120 | 390 | |
65 | 50 | 185 | 145 | 120 | 20 | 3 | 4-18 | 65 | 185 | 145 | 120 | 20 | 3 | 4-18 | 140 | 130 | 395 | |
80 | 65 | 200 | 160 | 135 | 20 | 3 | 8-18 | 80 | 200 | 160 | 135 | 20 | 3 | 8-18 | 160 | 135 | 400 | |
100 | 80 | 220 | 180 | 155 | 22 | 3 | 8-18 | 100 | 220 | 180 | 155 | 22 | 3 | 8-18 | 170 | 160 | 600 | |
125 | 100 | 250 | 210 | 185 | 22 | 3 | 8-18 | 125 | 250 | 210 | 185 | 22 | 3 | 8-18 | 190 | 190 | 620 | |
150 | 125 | 285 | 240 | 210 | 24 | 3 | 8-23 | 150 | 285 | 240 | 210 | 24 | 3 | 8-23 | 205 | 195 | 625 | |
200 | 150 | 340 | 295 | 265 | 26 | 3 | 12-23 | 200 | 340 | 295 | 265 | 26 | 3 | 12-23 | 240 | 230 | 798 | |
250 | 200 | 405 | 355 | 320 | 30 | 3 | 12-26 | 250 | 405 | 355 | 320 | 30 | 3 | 12-26 | 350 | 320 | 981 | |
300 | 250 | 460 | 410 | 375 | 30 | 4 | 12-26 | 300 | 460 | 410 | 375 | 30 | 4 | 12-26 | 350 | 320 | 1005 | |
A47H-25
| 20 | 15 | 105 | 75 | 55 | 16 | 2 | 4-14 | 20 | 105 | 75 | 55 | 16 | 2 | 4-14 | 100 | 85 | 270 |
25 | 20 | 115 | 85 | 65 | 16 | 2 | 4-14 | 25 | 115 | 85 | 65 | 16 | 2 | 4-14 | 100 | 85 | 270 | |
32 | 25 | 140 | 100 | 78 | 18 | 2 | 4-18 | 32 | 140 | 100 | 78 | 18 | 2 | 4-18 | 115 | 100 | 312 | |
40 | 32 | 150 | 110 | 85 | 18 | 3 | 4-18 | 40 | 150 | 110 | 85 | 18 | 3 | 4-18 | 120 | 110 | 320 | |
50 | 40 | 165 | 125 | 100 | 20 | 3 | 4-18 | 50 | 165 | 125 | 100 | 20 | 3 | 4-18 | 135 | 120 | 390 | |
65 | 50 | 185 | 145 | 120 | 22 | 3 | 8-18 | 65 | 185 | 145 | 120 | 20 | 3 | 4-18 | 140 | 130 | 395 | |
80 | 65 | 200 | 160 | 135 | 24 | 3 | 8-18 | 80 | 200 | 160 | 135 | 20 | 3 | 8-18 | 160 | 135 | 400 | |
100 | 80 | 230 | 190 | 160 | 24 | 3 | 8-23 | 100 | 220 | 180 | 155 | 20 | 3 | 8-18 | 170 | 160 | 600 | |
125 | 100 | 270 | 220 | 188 | 28 | 3 | 8-26 | 125 | 250 | 210 | 185 | 22 | 3 | 8-18 | 190 | 190 | 620 | |
150 | 125 | 300 | 250 | 218 | 30 | 3 | 8-26 | 150 | 285 | 240 | 210 | 24 | 3 | 8-23 | 205 | 195 | 625 | |
200 | 150 | 360 | 310 | 278 | 34 | 3 | 12-26 | 200 | 340 | 295 | 265 | 26 | 3 | 12-23 | 240 | 230 | 798 | |
250 | 200 | 425 | 370 | 332 | 36 | 3 | 12-30 | 250 | 405 | 355 | 320 | 30 | 3 | 12-26 | 350 | 320 | 981 | |
300 | 250 | 485 | 430 | 390 | 40 | 4 | 16-30 | 300 | 460 | 410 | 375 | 30 | 4 | 12-26 | 350 | 320 | 1005 |
安全閥是一種安全保護(hù)用閥,安全閥的啟閉件受外力作用下處于常閉狀態(tài),當(dāng)設(shè)備或管道內(nèi)的介質(zhì)壓力升高,超過(guò)規(guī)定值時(shí)自動(dòng)開(kāi)啟,通過(guò)向系統(tǒng)外排放介質(zhì)來(lái)防止管道或設(shè)備內(nèi)介質(zhì)壓力超過(guò)規(guī)定數(shù)值。安全閥屬于自動(dòng)閥類,安全閥主要用于鍋爐、壓力容器和管道上,控制壓力不超過(guò)規(guī)定值,對(duì)人身安全和設(shè)備運(yùn)行起重要保護(hù)作用。
安全閥閥瓣開(kāi)啟高度可分為微啟式安全閥和全啟式安全閥,微啟式安全閥的開(kāi)啟行程高度為:≤0.05d0(zui小排放喉部口徑);全啟式安全閥開(kāi)啟高度為≤0.25d0(zui小排放喉部口徑)。
安全閥按結(jié)構(gòu)形式來(lái)分,要分為垂錘式、杠桿式、彈簧式和先導(dǎo)式(脈沖式);按閥體構(gòu)造來(lái)分,可分為封閉式和不封閉式兩種。封閉式安全閥即排除的介質(zhì)不外泄,全部沿著出口排泄到地點(diǎn),一般用在有毒和腐蝕性介質(zhì)中。對(duì)于空氣和蒸汽用安全閥,多采用不封閉式安全閥。對(duì)于安全閥產(chǎn)品的選用,應(yīng)按實(shí)際密封壓力來(lái)確定。對(duì)于彈簧式安全閥,在一種公稱壓力(PN)范圍內(nèi),具有幾種工作壓力級(jí)的彈簧,訂貨時(shí)除注明安全閥型號(hào)、名稱、介質(zhì)和溫度外,尚應(yīng)注明閥體密封壓力,沒(méi)提供整定壓力按照zui大密封壓力供貨。
安全閥的安裝和維護(hù)應(yīng)注意以下事項(xiàng):
1.各種安全閥都應(yīng)垂直安裝。 2.安全閥出口處應(yīng)無(wú)阻力,避免產(chǎn)生受壓現(xiàn)象。
3.安全閥在安裝前應(yīng)專門測(cè)試,并檢查其官密封性。 4.對(duì)使用中的安全閥應(yīng)作定期檢查
歡迎您訪問(wèn)我們的科捷閥門【https://www.kejiev.com】,如有任何疑問(wèn).可以致電給我們公司,我們一定會(huì)盡心盡力為您提供優(yōu)質(zhì)的服務(wù)。: