針劑安瓿氧含量檢測(cè)儀
針劑安瓿氧含量檢測(cè)儀產(chǎn)品說(shuō)明
針劑測(cè)氧儀 食品包裝袋測(cè)氧儀 食品包裝氧含量測(cè)定儀
型號(hào)G80092
產(chǎn)品簡(jiǎn)介:該型號(hào)儀器適用于制藥廠(chǎng)針劑安瓿中的氧含量測(cè)定,食品行業(yè)袋裝食品以及罐頭食品包裝中的氧含量測(cè)定,適用于小劑量包裝及小劑量環(huán)境等各種場(chǎng)合下氧含量測(cè)定,并可作農(nóng)作物、動(dòng)物的呼吸實(shí)驗(yàn)的氧量控制。
采用極譜隔膜式氧電極為傳感器,采用*的中、大規(guī)模集成電路及3位半LED高亮度數(shù)字顯示器制造,它具有上限、下限數(shù)字撥盤(pán)預(yù)置設(shè)定,聲-光報(bào)警;上下限兩路控制觸點(diǎn)輸,自動(dòng)穩(wěn)零等功能,可使被控系統(tǒng)的氧含量在某一給定范圍內(nèi)。本廠(chǎng)生產(chǎn)的氧電極獲中國(guó)。使用該項(xiàng)后,儀器的穩(wěn)定性,比原儀器都有很大的提高。該型號(hào)儀器適用于制藥廠(chǎng)針劑安瓿中的氧含量測(cè)定,食品行業(yè)袋裝食品以及罐頭食品包裝中的氧含量測(cè)定,適用于小劑量包裝及小劑量環(huán)境等各種場(chǎng)合下氧含量測(cè)定,并可作農(nóng)作物、動(dòng)物的呼吸實(shí)驗(yàn)的氧量控制。
技術(shù)指標(biāo)
l、量程范圍:
0—25%0-5%
2、精度:
±O.1%(被測(cè)氣體氧含量良0-l%時(shí))
±O.2%(被測(cè)氣體氧含量在1%—25%時(shí))
3、zui小檢測(cè)量:O.1%
4、響應(yīng)時(shí)間:10秒(90響應(yīng)20℃時(shí))
5、電極壽命:①存放壽命三年左右(主要這電解液干)
②使用壽命:因環(huán)境的污染程度和氣體處理是否干凈而定。醫(yī)院高壓氧艙內(nèi)使用一般為二年左右;
6、zui小被測(cè)氣體積:針劑安瓿1-2毫升
7、穩(wěn)定性:48小時(shí)內(nèi)漂移小于±O.3%氧含量
8、控制輔點(diǎn)容量:AC220V2A
9、報(bào)警點(diǎn)控制精度:未尾1個(gè)字
10、使用溫度:0~40℃
ll、相度濕度:<95%
12、電源:220V±15%
13、記錄輸出:0~10mA或4—20mA(訂貨時(shí)注明)
14、功耗≤5W
15、外形尺寸:長(zhǎng)285×高110×深240毫米
安裝尺寸:280*100*230
16、重量:約3.6公斤
三、工作原理:
儀器由氧電極、放大器、摸似比較器、報(bào)警器四部分組成。氧電極:為極譜隔膜式,采用鉑金為陰極,銀氯化銀為陽(yáng)極,以聚四氟乙稀為滲透隔離膜,氣樣中氧可透過(guò)薄膜到達(dá)陰極,在650mV的極化電壓下發(fā)生如下反應(yīng)。
陰極:O2+2H2O+4e4OH
陽(yáng)極:Ag+CLAgCL
2反映可迅速達(dá)到平衡,同時(shí)產(chǎn)生一個(gè)極限擴(kuò)散電流,此電流的大小正比于氣樣中的氧分壓。此電流通過(guò)放大器放大,推動(dòng)顯示屏,顯示出氣樣中氧含量,同時(shí)輸出0—10mA電流供外接記錄儀作記錄,資料可存檔。另一路經(jīng)比較器比較推動(dòng)繼電器,當(dāng)氧含量超過(guò)設(shè)定值時(shí),儀器發(fā)出聲光報(bào)警,同時(shí)控制上限控制觸點(diǎn)輸出
The product description
Injection of oxygen meter food sack oxygen meter food packaging oxygen content meter injection ampoule oxygen content detector
Model G80092
Product introduction: the instrument models applicable to pharmaceutical injection ampoule determination of oxygen in the food industry food bags as well as the determination of oxygen in the canned food packaging, applicable to small doses of packaging and small dose of environment all sorts of asions such as oxygen content determination, and can make crops, animals, breathe the oxygen control.
By polarographic diaphragm type oxygen sensor was, USES the advanced medium and large scale integrated circuit and three and a half high brightness LED digital display, it has a upper limit and lower limit set, digital dial preset sound - light alarm; Upper and lower two way contact to lose control, automatic stable zero, and other functions, can make the controlled system of the oxygen content in a given range. The factory production of oxygen electrode by China patent. After use the patent, the stability of the instrument, compared to the original instruments has greatly improved. The instrument models applicable to pharmaceutical injection ampoule determination of oxygen in the food industry food bags as well as the determination of oxygen in the canned food packaging, applicable to small doses of packaging and small dose of environment all sorts of asions such as oxygen content determination, and can make crops, animals, breathe the oxygen control.
Technical indicators
L, scope of range:
0-25% 0-5%
2, precision:
Plus or minus o. 1% good measured gas oxygen content (0 - l %)
+ o. 2% (measured gas oxygen content in 1% - 1%)
3, the minimum detectable amount: o. 1%
4, response time: 10 seconds (20 ℃) 90 response
5, electrode life: (1) for about 3 years of life (mainly the electrolyte dry)
(2) the service life: because of environmental pollution and gas processing is clean. Hyperbaric oxygen chamber using general hospital for two years or so;
6, minimum air volume to be tested: 1-2 ml ampoule ampoule
7, stability, drift is less than 48 hours + o. 3% oxygen content
8, auxiliary control points capacity: AC220V2A
9, the emergency alarm control precision: not one word
10, using temperature: 0 ~ 40 ℃
Ll, degree of humidity: < 95%
12, the power supply: 220 v + 15%
13, record output: 0 ~ 10 ma, or 4-20 ma (when ordering specify)
14, 5 w or less power consumption
15, appearance size: 285 * 110 * 240 mm deep
Installation size: 280 * 100 * 100
16, weight: 3.6 kg
Third, how it works:
Instrument by oxygen electrode, amplifier, touch as the comparator, alarm of four parts. Oxygen electrode: for polarographic diaphragm type, using platinum as the cathode, silver and silver chloride as the anode, ptfe to ration for isolation membrane, oxygen in the gas sample can be through the membrane to the cathode, the following reaction under polarization voltage of 650 mv.
Cathode: O2 + 2 h2o + 4 e4oh
Anode: Ag + CLAgCL
2 reflect can rapidly balance, produce a limiting diffusion current at the same time, the current is proportional to the size of the oxygen partial pressure in the gas sample. The current through the amplifier amplification, promote display, show that oxygen content in gas samples, at the same time 0-10 ma current for the external recorder for recording, data can be archived. Another path comparator compares drive relay, when the oxygen content is more than the set value, send out sound and light alarm instrument, control limit control contact output at the same time
售后服務(wù)承諾:
1、服務(wù)宗旨:快速、果斷、準(zhǔn)確、周到、*
2、服務(wù)目標(biāo):服務(wù)質(zhì)量贏得用戶(hù)滿(mǎn)意
3、服務(wù)效率:保修期內(nèi)或保修期外如設(shè)備出現(xiàn)故障,供方在接到通知后,1-3個(gè)工作日內(nèi)予以解決。 用戶(hù)可以通過(guò)售后咨詢(xún)有關(guān)技術(shù)問(wèn)題,并得到明確的解決方案
4、服務(wù)原則:儀器儀表產(chǎn)品保修期為1年,在保修期內(nèi)供方將免費(fèi)維修和更換屬質(zhì)量原因造成的零部件損壞,保修期外零部件的損壞,提供的配件只收成本費(fèi),由需方人為因素 造成的設(shè)備損壞,供方維修或提供的配件均按成本價(jià)計(jì)。