- General Information
The non influenced by environmental variations system application is now preferred in the level measurements field. For this reason the SGM-LEKTRA developed the RWL51 unity. |
Non-contact level measurements | HART com. protocol | ||
Suitable for liquids levelmeasurement | 24Vdc power supply | ||
Configuration via menu-driven | Mechanical protection: IP67 | ||
matrix display (plug-in) | Output: 4÷20mA analog output |
- Technical Data
Housing material | Al |
Mechanical installation | 1? ”GAS M or 2”GAS M (depending on model) |
Protection degree | IP67 |
Electrical connection | Internal push connectors |
Working temperature | -30° ÷ +130°C / -40° ÷ +150°C (depending on model) |
Pressure | from -1 to 40bar |
Power supply | 24Vdc |
Analog output | 4÷20mA, max 750ohm (4-wire) |
Digital communication | HART |
Max measure range | ?10 Rigid rod, max 3m; ?4mm rope, max 10m; ?6mm rope, max. 30m |
Best accuracy | ±10mm |
Resolution | 1mm |
Calibration | via VL602 or by HART |
LCD Display | Plug-in display/keyboard 4 buttons matrix LCD |