丹富斯靜態(tài)平衡閥亦稱平衡閥、手動平衡閥、數(shù)字鎖定平衡閥、雙位調(diào)節(jié)閥等,它是通過改變閥芯與閥座的間隙靜態(tài)平衡閥(開度),來改變流經(jīng)閥門的流動阻力以達到調(diào)節(jié)流量的目的,其作用對象是系統(tǒng)的阻力,靜態(tài)平衡閥能夠?qū)⑿碌乃堪凑赵O(shè)計計算的比例平衡分配,各支路同時按比例增減,仍然滿足當(dāng)前氣候需要下的部份負荷的流量需求,起到熱平衡的作用。 靜態(tài)平衡閥結(jié)構(gòu)圖/丹富斯靜態(tài)平衡閥銷售
靜態(tài)平衡閥是一種具有數(shù)字鎖定特殊功能的調(diào)節(jié)型閥門,采用直流型閥體結(jié)構(gòu),具有更好的等百分比流量特性,能夠合理地分配流量,有效地解決供熱(空調(diào))系統(tǒng)中存在的室溫冷熱不均問題。同時能準(zhǔn)確地調(diào)節(jié)壓降和流量,用以改善管網(wǎng)系統(tǒng)中液體流動狀態(tài),達到管網(wǎng)液體平衡和節(jié)約源的目的。閥門設(shè)有開啟度指示、開度鎖定裝置及用于流量測定的測壓小閥,只要在各支路及用戶入口裝上適當(dāng)規(guī)格的平衡閥,并用智能儀表進行一次性調(diào)試后鎖定,將系統(tǒng)的總水量控制在合理的范圍內(nèi)、從而克服了“大流量,小溫差”的不合理現(xiàn)象。 既可安裝在供水管上,也可以安裝在回水管上,一般要安裝在回水管上,尤其對于高溫環(huán)路,為方便調(diào)試,更要裝在回水管上,安裝了平衡閥的供(回)水管不必再設(shè)截止閥。
丹富斯靜態(tài)平衡閥的性能及特點
1、優(yōu)秀的調(diào)節(jié)性能;
2、優(yōu)秀的截止功能;
3、精確到1/10圈的開啟圈數(shù)顯示;
4、理論流量特性曲線為等百分比(近似)特性,當(dāng)閥權(quán)度為30-50%時,實際流量特性為線性;
5、具備開度鎖定功能,非物業(yè)管理人員無法改變設(shè)定狀態(tài);
6、可方便有效地對壓力、流量進行調(diào)節(jié),配套智能儀表可方便地顯示工作壓差與流量,指導(dǎo)和記錄平衡調(diào)節(jié)方案; 靜態(tài)平衡閥結(jié)構(gòu)圖/丹富斯靜態(tài)平衡閥銷售
7、聚四氟乙烯密封,密封性能可靠,使用壽命長;
8、根據(jù)其開度百分比和閥門前后壓差,可計算通過閥門的流量;
9、內(nèi)部元件用不銹鋼、銅合金制造,抗銹蝕性能強;
10、內(nèi)升降閥桿無須預(yù)留操作空間;
Dan fuss static balance valve which is also called the balance valve, manual balance valve, digital locked balance valve, two position regulator, etc, it is by changing the clearance between the valve core and valve seat static balancing valve (opening), to alter the flow through the valve the flow resistance in order to achieve the purpose of flow adjustment, its object is the system resistance, static balancing valve to the new water allocation proportion according to the design and calculation of balance, each branch in proportion to increase or decrease at the same time, still can meet the needs of the current climate under part load of traffic demand, have the effect of thermal equilibrium.
Static balancing valve is a kind of external regulation valve with digital lock special functions, adopts dc type valve body structure, has better equal percentage flow characteristic, to reasonably allocate bandwidth, effectively solve the heating (air conditioning) room temperature is uneven and problems that exist in the system. Can accuray adjust the pressure drop and flow, at the same time to improve fluid flow state in pipeline system, achieve the goal of pipeline fluid balance and save the source. Of the opening of the valve opening instructions, locking devices and a small valve used for flow measurement of pressure, as long as in the selection and user entry fitted with appropriate specifications of the balance valve, with special inligent instrument for the disposable lock after debugging, the system of the total water control in a reasonable range, thus overcome the \"big flow rate, small temperature difference\" unreasonable phenomenon. Can be installed on the water supply pipe, also can be installed on the return pipe, generally to be installed on the return pipe, especially for high temperature loop, in order to facilitate debugging, more on the return pipe is loaded, installed the balancing valve for (back) to the pipe don't have to set a cut-off valve.
Dan fuss performance and characteristics of static balancing valve
1, good regulation performance;
2, good as function;
3, accurate to open 1/10 circle number display;
Four flow characteristic curve, the theory of equal percentage (approximate) feature, when the right degree of 30-50%, the actual flow characteristics for linear;
5, have the opening lock function, the property management personnel can't change setting state;
6, the pressure and flow rate can be effectively regulated, form a complete set of inligent instrument can easily display working pressure difference and flow, instruction and record balance regulation scheme;
7, ptfe sealing, reliable sealing performance, long service life;
8, according to its opening percentage and valve pressure difference before and after, can be calculated by the flow valves.
9, internal components made of stainless steel, copper alloy, corrosion resistance is strong;
Within 10, lift stem without reserve operation space;