millipore濾芯CGEP72TP3
Millipore Express® SHF Cartridge Filter 20 in. 0.2 µm Code 7 Silicone
概述
Replacement Information |
---|
規(guī)格
Description | |
---|---|
Catalogue Number | CGEP72TP3 |
Trade Name |
|
Description | Millipore Express® SHF Cartridge Filter 20in. 0.2µm Code 7 Silicone |
References |
---|
Product Information | |
---|---|
Device Configuration | Cartridge |
Maximum Inlet Pressure, bar (psi) | Forward- 7 bar (100 psi) @ 25°C; 1.7 bar (25 psi) @ 80°C; 0.35 bar (5 psi) @ 135°C; Reverse- 2.07 bar (30 psi) @ 25°C; 0.07 bar (1 psi) @ 135°C |
Cartridge Code | Code7 |
Good Manufacturing Practices | These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices. |
Applications |
---|
Biological Information | |
---|---|
Bacterial Endotoxins | Aqueous extraction contains ≤0.25EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test |
Media | Millipore Express® SHF |
Sterilization | 25 forward or 22 forward and 3 reverse SIP cycles of 30min @ 135°C; 25 autoclave cycles of 60min @ 126°C |
Bacterial Retention | Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10?CFU/cm2 using ASTM®F838 methodology. |
Wettability | Hydrophilic |
Physicochemical Information | |
---|---|
Pore Size | 0.2 µm |
Air Diffusion at 23°C | ≤60mL/min @ 2.75bar (40psig) in water |
Bubble Point at 23°C | ≥4000mbar (58psig) air with water |
Indirect Food Additive | All component materials meet the FDA Indirect Food Additive requirements cited in 21CFR177-182. |
Maximum Differential Pressure | Forward: 6900 mbar (100 psi) @ 25°C; 1700 bar (25 psi) @ 80°C; 340 mbar (5 psi) @ 135°C. Reverse: 2100 mbar (30 psi) @ 25°C, 69 mbar (1 psi) @ 135°C |
Non-Fiber Releasing | This product was manufactured with a Millipore Express® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21CFR210.3(b)(6). |
TOC/Conductivity | After sterilization and a controlled water flush of 20L, samples exhibited less than 500ppb TOC per USP <643> and less than 1.3µS/cm per USP <645> at 25°C. |
USP Bacterial Endotoxins | A sample aqueous extraction contains less than 0.25EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test. |
Dimensions | |
---|---|
Cartridge Nominal Length | 20 in. (50 cm) |
Diameter | 6.9 cm (2.7 in.) |
Filtration Area | 1.1 m2 |
Device Size | 20 in. |
Materials Information | |
---|---|
Chemistry |
|
Device Material |
|
Seal Material | Silicone (SI) |
Support Material | Polypropylene |
Packaging Information | |
---|---|
Material Size | 3 |
Material Package | Double Easy-Open bag |